Straight Mayo Scissors 15 cm Black Edition

SKU
13.207.12

15 cm Straight Mayo Scissors Black Edition, with a glossy finish, high resistance and precise cutting. Its Black Edition stainless steel coating enhances durability and corrosion resistance. The zipper closure improves safety, and its structure ensures a precise cut in surgical procedures.

DIMENSIONS: 15 x 6.4 cm

TIP OF BLADE: straight

€15.90 Taxes not included

MAYO STRAIGHT SCISSORS BLACK EDITION 15CM

The Mayo Straight Scissors Black Edition 15 cm stand out for their ergonomic design and glossy black finish, which facilitates cleaning and allows easy detection of stains. Their ratchet lock enhances safety, and their structure ensures a precise cut in surgical procedures.

The new professional instrument range Black Edition from Herbitas ensures greater durability of the instruments with a unique surface coating. This coating gives stainless steel a harder consistency, with less risk of deformation. Furthermore, it not only improves appearance but also provides high resistance to corrosion, extending its lifespan.

USAGE INDICATIONS:
Professional use in surgical procedures for cutting tissues and medical materials.


TECHNICAL SPECIFICATIONS:

  • BRAND: Herbitas
  • MATERIAL: Stainless steel Black Edition
  • STERILIZABLE: Yes
  • WEIGHT: 20 g
  • DIMENSIONS: 15 x 6.4 cm
  • BLADE TYPE: Straight


STORAGE:

  • Store at room temperature in a dry place.
  • Protect from heat, intense light, and dust.

WARNINGS:

  • Professional use only.
  • The instrument must be cleaned, disinfected, and sterilized by the clinician before first use and after each use.
  • Check its proper functioning and perfect condition before using the product.


CLEANING AND MAINTENANCE:

Initial recommendations:

  • Perform a visual and mechanical inspection of the new surgical instrument.
  • Visible dirt should be removed as soon as possible to prevent residues from drying.
  • Avoid long waiting times for cleaning and disinfecting the instrument.

Preliminary manual cleaning:

  • Initially, it should be washed by hand with neutral soap.
  • In the operating room, the most apparent dirt should be removed as soon as possible to prevent encrustation, which could lead to corrosion.
  • It is essential to avoid long waiting times before reprocessing (<1h).
  • Dry cleaning is preferable as medical devices can suffer from corrosion if submerged for long periods in solutions.
  • If dry cleaning is insufficient, it will be necessary to wash them with cold water (< 40ºC), including cavities, grooves, and hard-to-reach holes, which should be washed with pressurized water. Make sure no areas are left unwashed. A soft-bristled plastic brush may be used.
  • Thoroughly dry with an absorbent lint-free cloth or compressed air.

Cleaning and disinfection:

  • Immerse the products in a solution of distilled water with a suitable disinfectant in an ultrasonic bath or a cleaning tank.
  • Follow the manufacturer’s instructions for the disinfectant to select the washing program, temperature, and time.
  • Clean instruments with movable joints in the open position or move the joints to avoid "shadow areas." Follow the manufacturer's instructions for disassembling detachable instruments.
  • The instruments must be placed with a minimum separation between them in the cleaning container and avoid overlapping to prevent damage caused by impact.
  • At the end of the disinfection program, rinse the products thoroughly with distilled cold water, paying particular attention to cavities, grooves, and hard-to-reach holes, preferably with pressurized water.
  • Thoroughly dry with an absorbent lint-free cloth or compressed air.

Lubrication:

  • Use the Sterilit Protector Instrumental (ref. 13.859.1 and 13.859.2) to protect the instruments.
  • Attach the supplied white plastic tube to the spray and apply the aerosol oil directly to the joint area or hard-to-reach zones.
  • Open and close the instrument several times to distribute the oil evenly and remove excess oil with a lint-free cloth. Then, proceed with the sterilization of the instrument, as the oil film is permeable to steam. It will act as a lubricant and anti-corrosive without leaving stains on the instruments.

Sterilization:

  • Sterilize the products in accordance with applicable national requirements.
  • Sterilization of the products must be carried out in suitable sterilization packaging.