Mosquito Forceps without teeth Black Edition

SKU
13.309.23

Mosquito Forceps Black Edition without teeth, straight, 12.5 cm, with ratchet lock and serrated tip for better grip. Its surface coating provides greater corrosion resistance and lower risk of deformation.

DIMENSIONS: 12.5 x 6.4 cm

TIP OF THE FORCEPS: serrated, 2.2 cm in length

€8.65 Taxes not included

STRAIGHT MOSQUITO FORCEPS WITHOUT TEETH BLACK EDITION

The Straight Mosquito Black Edition Forceps without Teeth (12.5 cm) stands out for its ergonomic design, glossy black finish, and smooth texture, making it easy to clean and detect stains. Made of Black Edition stainless steel, its surface coating provides greater resistance to corrosion and less chance of deformation. It features a ratchet lock for added security and a 2.2 cm serrated tip that improves grip during surgical procedures.

INDICATIONS FOR USE:
Professional use in surgical procedures requiring precision and firm holding of tissues or materials without damaging them.


TECHNICAL SPECIFICATIONS:

  • BRAND: Herbitas
  • MATERIAL: Black Edition stainless steel
  • STERILIZABLE: yes
  • WEIGHT: 20 g
  • DIMENSIONS: 12.5 x 6.4 cm
  • TIP TYPE: serrated, 2.2 cm in length


STORAGE:

  • Store at room temperature in a dry place.
  • Protect from heat, intense light, and dust.


WARNINGS:

  • For professional use only.
  • The instrument must be cleaned, disinfected, and sterilized by the clinician before first use and after each use.
  • Ensure proper functionality and perfect condition before use.


CLEANING AND CARE:

Initial Recommendations:

  • Perform a visual and mechanical inspection of the new surgical instrument.
  • Visible dirt should be removed as soon as possible to prevent residue from drying.
  • Avoid long waiting times before cleaning and disinfecting the instrument.

Preliminary Manual Cleaning:

  • Initially, it should be washed by hand with neutral soap.
  • In the operating room, the most visible dirt should be removed immediately to avoid encrustation that could lead to corrosion.
  • It is essential to avoid long waiting times for reprocessing (<1h).
  • Dry cleaning is preferable, as medical devices may suffer corrosion if immersed in solutions for long periods.
  • If dry cleaning is insufficient, wash with cold water (< 40°C), including cavities, grooves, and hard-to-reach holes, which should be cleaned using pressurized water. Avoid leaving unwashed areas. A soft-bristle plastic brush can be used.
  • Thoroughly dry with an absorbent, lint-free cloth or compressed air.

Cleaning and Disinfection:

  • Submerge the products in a solution of distilled water with an appropriate disinfectant in an ultrasonic bath or container.
  • Follow the manufacturer’s instructions for the disinfectant product to select the washing program, temperature, and duration.
  • Clean instruments with movable joints in the open position or by moving the joints to avoid “shadow areas.” Follow the manufacturer’s instructions for disassembling detachable instruments.
  • Instruments should be placed with minimal spacing between them in the cleaning container and should not overlap to avoid damage due to impacts.
  • At the end of the disinfection process, rinse the instruments thoroughly with plenty of cold distilled water, paying special attention to cavities, grooves, and hard-to-reach holes, preferably using pressurized water.
  • Thoroughly dry with an absorbent, lint-free cloth or compressed air.

Lubrication:

  • Use Sterilit Protector Instrumental (ref. 13.859.1 and 13.859.2) to protect the instrument.
  • Attach the provided white plastic tube to the spray and apply the aerosol oil directly to the joint area or hard-to-reach spots.
  • Open and close the instrument several times to distribute the oil evenly and remove excess oil with a lint-free cloth. Then, proceed with the sterilization of the instrument, as the oil film is permeable to steam. It acts as a lubricant and anti-corrosion agent without leaving stains on the instruments.

Sterilization:

  • Sterilize the instruments considering the applicable national requirements.
  • Sterilization must be carried out in appropriate sterilization packaging.