Instrument Set and Box Black Edition. Discover the new Black Edition professional instrument range by Herbitas, designed to offer maximum resistance and a sophisticated aesthetic. Thanks to its exclusive surface coating, stainless steel gains greater hardness, minimizing the risk of deformation. Its high corrosion resistance ensures exceptional durability.
The Black Edition Instrument Set is the ideal choice for professionals seeking quality, precision, and an exclusive design.
CONTENTS: the set includes the following references from the Black Edition range: instrument box (12.419.6), straight Mayo scissors (13.207.12), straight mosquito forceps (13.309.23), Adson forceps (13.303.13), and scalpel handle No. 3 (13.004.9).
Special Price€62.79Regular Price€69.75Taxes not included
BLACK EDITION INSTRUMENT SET – PROFESSIONAL QUALITY AND DURABILITY
The new professional instrument range Black Edition from Herbitas ensures greater durability of the instruments thanks to a unique surface coating. This coating gives stainless steel a harder consistency, with less risk of deformation. Moreover, it not only improves the appearance but also provides high resistance to corrosion, extending its lifespan.
This innovative finish not only enhances the appearance of the instruments but also provides high resistance to corrosion, increasing their longevity and ensuring optimal performance with every use.
TECHNICAL SPECIFICATIONS:
BRAND: Herbitas
MATERIAL: Stainless steel Black Edition
STERILIZABLE: Yes
BOX DIMENSIONS: 17.5 x 8 x 4 cm
CONTENTS:The set includes the following Black Edition references: instrument box (12.419.6), straight Mayo scissors (13.207.12), straight Mosquito forceps (13.309.23), Adson forceps (13.303.13), and scalpel handle No.3 (13.004.9).
COLOR: Black
FINISH: Glossy.
CLEANING AND CARE:
Initial recommendations:
Perform a visual and mechanical inspection of the new surgical instrument.
Visible dirt should be removed as soon as possible to prevent residue from drying.
Avoid long waiting times before cleaning and disinfecting the instrument.
Preliminary manual cleaning:
Initially, it should be washed by hand with neutral soap.
In the operating room, the most apparent dirt should be removed as soon as possible to avoid encrustation that could lead to corrosion.
It is essential to avoid long waiting times before reprocessing (<1h).
Dry cleaning is preferable, as medical devices can suffer corrosion if submerged for long periods in solutions.
If dry cleaning is insufficient, washing with cold water (< 40ºC) is necessary, including cavities, grooves, and hard-to-reach holes, which should be cleaned with pressurized water. Ensure no areas are left uncleaned. A soft-bristled plastic brush may be used.
Thoroughly dry with an absorbent lint-free cloth or compressed air.
Cleaning and disinfection:
Immerse the instruments in a solution of distilled water with a suitable disinfectant in an ultrasonic bath or cleaning tank.
Follow the manufacturer’s instructions for selecting the washing program, temperature, and time.
Clean instruments with movable joints in the open position or by moving the joints to avoid “shadow areas.” Follow the manufacturer's instructions for disassembling detachable instruments.
The instruments must be placed with a minimum separation between them in the cleaning container and avoid overlapping to prevent damage due to impact.
At the end of the disinfection program, rinse the products thoroughly with distilled cold water, paying special attention to cavities, grooves, and hard-to-reach holes, preferably with pressurized water.
Thoroughly dry with an absorbent lint-free cloth or compressed air.
Lubrication:
Use the Sterilit Protector Instrumental (ref. 13.859.1 and 13.859.2) to protect the instrument.
Attach the provided white plastic tube to the spray and apply the aerosol oil directly to the joint area or hard-to-reach zones.
Open and close the instrument several times to distribute the oil evenly and remove excess oil with a lint-free cloth. Then, proceed with sterilization, as the oil film is steam-permeable. It will act as a lubricant and anti-corrosive without leaving stains on the instruments.
Sterilization:
Sterilize the instruments in accordance with applicable national requirements.
Sterilization of the instruments must be carried out in suitable sterilization packaging.
https://herbitas.com/en/instrument-set-black-edition.html7465Instrument Set Black Edition<style>#html-body [data-pb-style=NT315V0]{justify-content:flex-start;display:flex;flex-direction:column;background-position:left top;background-size:cover;background-repeat:no-repeat;background-attachment:scroll}</style><div data-content-type="row" data-appearance="contained" data-element="main"><div data-enable-parallax="0" data-parallax-speed="0.5" data-background-images="{}" data-background-type="image" data-video-loop="true" data-video-play-only-visible="true" data-video-lazy-load="true" data-video-fallback-src="" data-element="inner" data-pb-style="NT315V0"><div data-content-type="text" data-appearance="default" data-element="main"><p> </p>
<h2><strong><span style="font-size: 28px; color: #000000;">BLACK EDITION INSTRUMENT SET – PROFESSIONAL QUALITY AND DURABILITY</span></strong></h2>
<p>The new professional instrument range <strong>Black Edition</strong> from Herbitas ensures <strong>greater durability of the instruments</strong> thanks to a unique surface coating. This coating gives stainless steel a <strong>harder consistency, with less risk of deformation</strong>. Moreover, it not only improves the appearance but also provides <strong>high resistance to corrosion, extending its lifespan</strong>.</p>
<p>This innovative finish not only enhances the appearance of the instruments but also provides high resistance to corrosion, increasing their longevity and ensuring optimal performance with every use.</p>
<p><br><strong>TECHNICAL SPECIFICATIONS:</strong></p>
<ul>
<li><strong>BRAND:</strong> Herbitas</li>
<li><strong>MATERIAL:</strong> Stainless steel Black Edition</li>
<li><strong>STERILIZABLE:</strong> Yes</li>
<li><strong>BOX DIMENSIONS:</strong> 17.5 x 8 x 4 cm</li>
<li><strong style="color: #333333;">CONTENTS:</strong> <span style="color: #333333;">The set includes the following Black Edition references: instrument box (12.419.6), straight Mayo scissors (13.207.12), straight Mosquito forceps (13.309.23), Adson forceps (13.303.13), and scalpel handle No.3 (13.004.9).</span></li>
<li><span style="color: #333333;"><strong>COLOR:</strong> Black</span></li>
<li><span style="color: #333333;"><strong>FINISH:</strong> Glossy.</span></li>
</ul>
<p> <br><strong>CLEANING AND CARE:</strong></p>
<p><strong>Initial recommendations:</strong></p>
<ul>
<li>Perform a visual and mechanical inspection of the new surgical instrument.</li>
<li>Visible dirt should be removed as soon as possible to prevent residue from drying.</li>
<li>Avoid long waiting times before cleaning and disinfecting the instrument.</li>
</ul>
<p><strong>Preliminary manual cleaning:</strong></p>
<ul>
<li>Initially, it should be washed by hand with neutral soap.</li>
<li>In the operating room, the most apparent dirt should be removed as soon as possible to avoid encrustation that could lead to corrosion.</li>
<li>It is essential to avoid long waiting times before reprocessing (<1h).</li>
<li>Dry cleaning is preferable, as medical devices can suffer corrosion if submerged for long periods in solutions.</li>
<li>If dry cleaning is insufficient, washing with cold water (< 40ºC) is necessary, including cavities, grooves, and hard-to-reach holes, which should be cleaned with pressurized water. Ensure no areas are left uncleaned. A soft-bristled plastic brush may be used.</li>
<li>Thoroughly dry with an absorbent lint-free cloth or compressed air.</li>
</ul>
<p><strong>Cleaning and disinfection:</strong></p>
<ul>
<li>Immerse the instruments in a solution of distilled water with a suitable disinfectant in an ultrasonic bath or cleaning tank.</li>
<li>Follow the manufacturer’s instructions for selecting the washing program, temperature, and time.</li>
<li>Clean instruments with movable joints in the open position or by moving the joints to avoid “shadow areas.” Follow the manufacturer's instructions for disassembling detachable instruments.</li>
<li>The instruments must be placed with a minimum separation between them in the cleaning container and avoid overlapping to prevent damage due to impact.</li>
<li>At the end of the disinfection program, rinse the products thoroughly with distilled cold water, paying special attention to cavities, grooves, and hard-to-reach holes, preferably with pressurized water.</li>
<li>Thoroughly dry with an absorbent lint-free cloth or compressed air.</li>
</ul>
<p><strong>Lubrication:</strong></p>
<ul>
<li>Use the Sterilit Protector Instrumental (ref. 13.859.1 and 13.859.2) to protect the instrument.</li>
<li>Attach the provided white plastic tube to the spray and apply the aerosol oil directly to the joint area or hard-to-reach zones.</li>
<li>Open and close the instrument several times to distribute the oil evenly and remove excess oil with a lint-free cloth. Then, proceed with sterilization, as the oil film is steam-permeable. It will act as a lubricant and anti-corrosive without leaving stains on the instruments.</li>
</ul>
<p><strong>Sterilization:</strong></p>
<ul>
<li>Sterilize the instruments in accordance with applicable national requirements.</li>
<li>Sterilization of the instruments must be carried out in suitable sterilization packaging.</li>
</ul></div></div></div>https://herbitas.com/media/catalog/product/1/2/12.419.9.jpg62.79instock69.7562.79106.96Herbitas000https://herbitas.com/media/catalog/product/1/2/12.419.9.jpg/Surgical Instruments/INSTRUMENTAL HERBITAS/Black Edition2025-03-20T10:58:08+0000shop1