Fine Point Flat Aesculap Nipper HF 476R

SKU
13.416.2
  • Buy 3 for €34.95 each and save 5%

Flat Nipper with Fine Tip for manicure and pedicure, specially designed for nail corners.

MEASUREMENTS: 11.5 cm.

TIP TYPE: fine.

€36.95 Taxes not included

FINE-TIPPED NIPPER FOR MANICURE AND PEDICURE

11.5 cm nipper made of stainless steel, designed for manicure and pedicure, especially effective for working in nail corners. Equipped with a jaw length of 1.2 cm (3/8”), this instrument meets the requirements for reuse and sterilization, ensuring high quality and precision in use.

INDICATIONS FOR USE OF THE NIPPER:

  • Instrument intended for manicure and pedicure.
  • Specifically designed for treating nail corners.

TECHNICAL SPECIFICATIONS:

  • BRAND: Aesculap.
  • MATERIAL: stainless steel.
  • STERILIZABLE: yes.
  • SIZE: 11.5 cm.
  • TIP TYPE: fine.
  • JAW LENGTH: 1.2 cm (3/8”).

PRESENTATION:
A pouch containing a stainless steel nipper.

STORAGE:
Store in a clean, dark, and dry environment.

WARNINGS:
Product supplied non-sterile.
Clean and sterilize the product before first use.

CLEANING AND CARE:

Initial Recommendations:

  • Perform a visual and mechanical inspection of new surgical instruments.
  • Visible dirt should be removed as soon as possible to prevent residue from drying.
  • Avoid long waiting times for cleaning and disinfection of the instruments.

Manual Pre-Cleaning:

  • Initially, wash by hand with neutral soap.
  • In the operating room, remove the most visible dirt as soon as possible to prevent incrustations that can cause corrosion.
  • Avoid long waiting times for reprocessing (<1h).
  • Dry cleaning is preferable since medical devices can corrode if submerged for long periods in solutions.
  • If dry cleaning is insufficient, wash with cold water (<40ºC), including cavities, grooves, and hard-to-reach holes, which should be cleaned with pressurized water. Avoid leaving uncleaned areas. Use a soft-bristle plastic brush.
  • Thoroughly dry with an absorbent cloth that leaves no residue or with compressed air.

Cleaning and Disinfection:

  • Immerse the products in a solution of distilled water with an appropriate disinfectant in an ultrasonic bath or tank.
  • Follow the disinfectant manufacturer’s instructions for selecting the washing program, temperature, and time.
  • Clean instruments with movable joints in the open position or move the joints to avoid "shadow areas." Follow the manufacturer’s instructions for disassembling removable instruments.
  • Place the instruments with minimal separation in the cleaning container and avoid overlapping to prevent damage caused by impacts.
  • At the end of the disinfection program, rinse thoroughly with cold distilled water, paying special attention to cavities, grooves, and hard-to-reach holes, if possible using pressurized water.
  • Thoroughly dry with an absorbent cloth that leaves no residue or with compressed air.

Lubrication:

  • Use Sterilit Instrument Protector (ref. 13.859.1 and 13.859.2) to protect the instrument.
  • Attach the white plastic tube provided with the spray and apply the aerosol oil directly to the joint area or hard-to-reach spots.
  • Open and close the instrument several times to evenly distribute the oil and remove excess oil with a lint-free cloth. Then proceed to sterilize the instruments as the oil film is steam-permeable. It acts as a lubricant and anticorrosive without leaving stains on the instruments.

Sterilization:

  • Sterilize the products following the relevant national requirements.
  • Sterilization should be carried out in an appropriate sterilization container.

upsell products