Triple-joint nipper made of stainless steel, available in two sizes (12.5 cm and 15 cm), designed for precise cutting of nails and cuticles, even in hard-to-reach areas.
HANDLE TYPE: grooved for better grip.
DIMENSIONS:
REF. 13.427.3 (15 CM): 15.0 x 8.5 cm (length x width).
REF. 13.427.7 (12.5 CM): 12.5 x 8.5 cm (length x width).
The H250 Triple Joint Nipper, made of stainless steel, is designed to cut nails and cuticles with precision. Available in two sizes (12.5 cm and 15 cm), it features a grooved handle for better grip and safety. Sterilizable, reusable, and latex-free, it is an ideal tool for professional use. Supplied with a plastic case for storage.
INSTRUCTIONS FOR USING THE NIPPERS:
Designed for cutting nails and cuticles
Professional use.
TECHNICAL CHARACTERISTICS:
BRAND: Herbitas
MATERIAL: stainless steel
STERILIZABLE: yes
SPRING TYPE: triple joint.
HANDLE TYPE: grooved for better grip.
REF. 13.427.3 (15 CM):
WEIGHT: 144 g
DIMENSIONS: 15.0 x 8.5 cm ± 0.5 cm (length x width).
MOUTH LENGTH: 20 mm ± 1 mm
MOUTH WIDTH: open: 35 mm ± 1 mm / 39 mm ± 1 mm. Closed: 8.5 mm ± 0.5 mm / 10.75 mm ± 0.5 mm.
REF. 13.427.7 (12.5 CM):
WEIGHT: 86 g
DIMENSIONS: 12.5 x 8.5 cm ± 0.5 cm (length x width).
MOUTH LENGTH: 15 mm ± 1 mm.
MOUTH WIDTH: open: 21 mm ± 1 mm. Closed: 6.5 mm ± 0.5 mm / 8.0 mm ± 0.5 mm.
PRESENTATION: A plastic case containing a triple joint nipper.
STORAGE:
Store in a cool, dry place.
Protect from direct sunlight.
WARNINGS:
Product supplied in non-sterile conditions.
Requires cleaning, disinfection, and sterilization before first use and after each use.
Keep out of reach of children. For exclusive use by trained and qualified personnel.
Visually and functionally inspect before each use.
Remove broken, damaged, or rusted instruments.
CLEANING AND CARE:
Initial recommendations:
Perform a visual and mechanical check of new surgical instruments.
Visible dirt must be removed as soon as possible to prevent residue from drying.
Avoid long waiting times for cleaning and disinfection of instruments.
Manual preliminary cleaning:
Initially, wash by hand with neutral soap.
In the operating room, remove apparent dirt as soon as possible to prevent encrustation that may cause corrosion.
Avoid long waiting times for reprocessing (<1h).
Prefer dry cleaning, as medical devices may corrode if submerged for a long time in solutions.
If dry cleaning is insufficient, wash with cold water (<40ºC), including cavities, grooves, and hard-to-reach holes, using pressurized water if possible. Ensure no area is left uncleaned. A soft-bristle plastic brush can be used.
Thoroughly dry with an absorbent cloth that leaves no residue or with compressed air.
Cleaning and disinfection:
Immerse the products in a solution of distilled water with an appropriate disinfectant in an ultrasonic bath or a tank.
Follow the instructions established by the disinfectant manufacturer to select the washing program, temperature, and time.
Clean instruments with movable joints in an open position or by moving the joints to avoid "shadow areas." Follow the manufacturer's instructions to dismantle removable instruments.
Fix the instruments with minimal spacing in the cleaning container and avoid overlap to prevent damage from collisions.
At the end of the disinfection program, rinse the products thoroughly with cold distilled water, emphasizing cavities, grooves, and hard-to-reach holes of the instrument, using pressurized water if possible.
Thoroughly dry with an absorbent cloth that leaves no residue or with compressed air.
Lubrication:
Use Sterilit Protector Instrumental (ref. 13.859.1 and 13.859.2) to protect the instruments.
Attach the included white plastic tube to the spray and apply the oil directly to the joint area or hard-to-reach areas.
Open and close the instrument several times to distribute the oil evenly and remove the excess with a lint-free cloth. Then proceed to sterilize the instrument, as the oil film is permeable to steam. It will act as a lubricant and anti-corrosion agent without leaving stains on the instruments.
Sterilization:
Sterilize products in accordance with corresponding national requirements.
Product sterilization must be carried out in appropriate sterilization packaging.
https://herbitas.com/en/triple-joint-nipper-herbitas.html7358Triple-joint Nipper Herbitas<style>#html-body [data-pb-style=UES2XON]{justify-content:flex-start;display:flex;flex-direction:column;background-position:left top;background-size:cover;background-repeat:no-repeat;background-attachment:scroll}</style><div data-content-type="row" data-appearance="contained" data-element="main"><div data-enable-parallax="0" data-parallax-speed="0.5" data-background-images="{}" data-background-type="image" data-video-loop="true" data-video-play-only-visible="true" data-video-lazy-load="true" data-video-fallback-src="" data-element="inner" data-pb-style="UES2XON"><div data-content-type="text" data-appearance="default" data-element="main"><h2><strong><span style="font-size: 28px;">H250 TRIPLE JOINT NIPPER HERBITAS</span></strong></h2>
<p>The H250 Triple Joint Nipper, made of stainless steel, is designed to cut nails and cuticles with precision. Available in two sizes (12.5 cm and 15 cm), it features a grooved handle for better grip and safety. Sterilizable, reusable, and latex-free, it is an ideal tool for professional use. Supplied with a plastic case for storage.</p>
<p> </p>
<p><strong>INSTRUCTIONS FOR USING THE NIPPERS:</strong></p>
<ul>
<li>Designed for cutting nails and cuticles</li>
<li>Professional use.</li>
</ul>
<p> <br><strong>TECHNICAL CHARACTERISTICS:</strong></p>
<ul>
<li><strong>BRAND:</strong> Herbitas</li>
<li><strong>MATERIAL:</strong> stainless steel</li>
<li><strong>STERILIZABLE:</strong> yes</li>
<li><strong style="color: #333333;">SPRING TYPE:</strong><span style="color: #333333;"> triple joint.</span></li>
<li><strong style="color: #333333;">HANDLE TYPE:</strong><span style="color: #333333;"> grooved for better grip.</span></li>
</ul>
<p id="WX1Q1Q9"><span style="text-decoration: underline;"><strong>REF. 13.427.3 (15 CM):</strong></span></p>
<ul>
<li><strong>WEIGHT:</strong> 144 g</li>
<li><strong>DIMENSIONS:</strong> 15.0 x 8.5 cm ± 0.5 cm (length x width).</li>
<li><strong>MOUTH LENGTH:</strong> 20 mm ± 1 mm</li>
<li><strong>MOUTH WIDTH:</strong> open: 35 mm ± 1 mm / 39 mm ± 1 mm. Closed: 8.5 mm ± 0.5 mm / 10.75 mm ± 0.5 mm.<br><br></li>
</ul>
<p><span style="text-decoration: underline;"><strong>REF. 13.427.7 (12.5 CM):</strong></span></p>
<ul>
<li><strong>WEIGHT:</strong> 86 g</li>
<li><strong style="color: #333333;">DIMENSIONS:</strong><span style="color: #333333;"> 12.5 x 8.5 cm ± 0.5 cm (length x width).</span></li>
<li><strong style="color: #333333;">MOUTH LENGTH:</strong><span style="color: #333333;"> 15 mm ± 1 mm.</span></li>
<li><strong style="color: #333333;">MOUTH WIDTH:</strong><span style="color: #333333;"> open: 21 mm ± 1 mm. Closed: 6.5 mm ± 0.5 mm / 8.0 mm ± 0.5 mm.</span></li>
</ul>
<p> </p>
<p><strong>PRESENTATION:</strong><br>A plastic case containing a triple joint nipper.</p>
<p> <br><strong>STORAGE:</strong></p>
<ul>
<li>Store in a cool, dry place.</li>
<li>Protect from direct sunlight.<br> </li>
</ul>
<p><strong>WARNINGS:</strong></p>
<ul>
<li>Product supplied in non-sterile conditions.</li>
<li>Requires cleaning, disinfection, and sterilization before first use and after each use.</li>
<li>Keep out of reach of children.<br>For exclusive use by trained and qualified personnel.</li>
<li>Visually and functionally inspect before each use.</li>
<li>Remove broken, damaged, or rusted instruments.<br> <br><br></li>
</ul>
<h3><strong>CLEANING AND CARE:</strong></h3>
<p><strong>Initial recommendations:</strong></p>
<ul>
<li>Perform a visual and mechanical check of new surgical instruments.</li>
<li>Visible dirt must be removed as soon as possible to prevent residue from drying.</li>
<li>Avoid long waiting times for cleaning and disinfection of instruments.</li>
</ul>
<p><strong>Manual preliminary cleaning:</strong></p>
<ul>
<li>Initially, wash by hand with neutral soap.</li>
<li>In the operating room, remove apparent dirt as soon as possible to prevent encrustation that may cause corrosion.</li>
<li>Avoid long waiting times for reprocessing (<1h).</li>
<li>Prefer dry cleaning, as medical devices may corrode if submerged for a long time in solutions.</li>
<li>If dry cleaning is insufficient, wash with cold water (<40ºC), including cavities, grooves, and hard-to-reach holes, using pressurized water if possible. Ensure no area is left uncleaned. A soft-bristle plastic brush can be used.</li>
<li>Thoroughly dry with an absorbent cloth that leaves no residue or with compressed air.</li>
</ul>
<p><strong>Cleaning and disinfection:</strong></p>
<ul>
<li>Immerse the products in a solution of distilled water with an appropriate disinfectant in an ultrasonic bath or a tank.</li>
<li>Follow the instructions established by the disinfectant manufacturer to select the washing program, temperature, and time.</li>
<li>Clean instruments with movable joints in an open position or by moving the joints to avoid "shadow areas." Follow the manufacturer's instructions to dismantle removable instruments.</li>
<li>Fix the instruments with minimal spacing in the cleaning container and avoid overlap to prevent damage from collisions.</li>
<li>At the end of the disinfection program, rinse the products thoroughly with cold distilled water, emphasizing cavities, grooves, and hard-to-reach holes of the instrument, using pressurized water if possible.</li>
<li>Thoroughly dry with an absorbent cloth that leaves no residue or with compressed air.</li>
</ul>
<p><strong>Lubrication:</strong></p>
<ul>
<li>Use Sterilit Protector Instrumental (ref. 13.859.1 and 13.859.2) to protect the instruments.</li>
<li>Attach the included white plastic tube to the spray and apply the oil directly to the joint area or hard-to-reach areas.</li>
<li>Open and close the instrument several times to distribute the oil evenly and remove the excess with a lint-free cloth. Then proceed to sterilize the instrument, as the oil film is permeable to steam. It will act as a lubricant and anti-corrosion agent without leaving stains on the instruments.</li>
</ul>
<p><strong>Sterilization:</strong></p>
<ul>
<li>Sterilize products in accordance with corresponding national requirements.</li>
<li>Product sterilization must be carried out in appropriate sterilization packaging.</li>