Nipper H476
SKU
13.427.1
Nipper for nails and cuticles cutting, 11.5cm.
Quality at the best price!
€19.50
Taxes not included
The Herbitas H476 nail clippers, 11.5cm with flat cut are made of stainless steel.
The flat cutting jaw features a straight cutting edge perpendicular to the nail surface and is used for cutting nails straight.
ALICATES USAGE INDICATIONS:
- Cutting nails and cuticles.
- Manicure and pedicure product.
- Reusable. Allows sterilization.
TECHNICAL FEATURES:
BRAND: Herbitas
MATERIAL: Stainless steel
STERILIZABLE: Sterilizable product. Reuse allowed.
WEIGHT: 20g
MEASURES: Total length of 11.5 cm ± 0.5 cm
JAW LENGTH: Total length of 15 mm
JAW WIDTH: Open width: 7.75 mm ± 0.5 mm | Closed width: 6 mm ± 0.5 mm
TYPE OF TIP: Flat cut
SPRING TYPE: Foldable single plate
STOCKAGE:
STORAGE:
- Store at room temperature in a dry place.
- Protect from heat, intense light, and dust.
WARNINGS:
- Professional use.
- The instrument must be cleaned, disinfected, and sterilized by the clinician before first use and after each use.
- Check for proper functioning and perfect condition before using the product.
CLEANING AND CARE:
Initial Recommendations:
- Perform a visual and mechanical check of the new surgical instruments.
- Visible dirt should be removed as soon as possible to prevent residues from drying.
- Avoid long waiting times for cleaning and disinfecting the instruments.
Preliminary manual cleaning:
- Initially, it must be hand washed with mild soap.
- In the operating room, the most apparent dirt must be removed as soon as possible to avoid encrustation that can lead to corrosion.
- Long waiting times for reprocessing should be avoided (<1h).
- Dry cleaning is preferable as medical devices can corrode if immersed for a long time in solutions.
- If the dry process is insufficient, it will be necessary to wash them with cold water (<40ºC), including the cavities, grooves, and difficult-to-access holes that must be washed with pressurized water. Avoid leaving unwashed areas. You can use a soft plastic brush.
- Dry thoroughly with an absorbent cloth that leaves no residue or with compressed air.
Cleaning and disinfection:
- Immerse the products in a solution of distilled water with an appropriate disinfectant in an ultrasonic bath or tank.
- Follow the instructions provided by the manufacturer of the disinfectant product to select the washing program, temperature, and time.
- Clean instruments with movable joints in the open position or move the joints to avoid "shadow areas". Follow the manufacturer's instructions for disassembling removable instruments.
- The instruments must be placed with minimal separation in the cleaning container and avoid overlapping them to prevent damage from collisions.
- At the end of the disinfection program, wash the products thoroughly with plenty of cold distilled water, insisting thoroughly on the cavities, grooves, and difficult-to-access holes of the instrument, if possible with pressurized water.
- Dry thoroughly with an absorbent cloth that leaves no residue or with compressed air.
Lubrication:
- Use Sterilit Instrumental Protector (ref. 13.859.1 and 13.859.2) to protect the instruments.
- Attach the white plastic tube provided with the spray and apply the aerosol oil directly to the joint area or hard-to-reach areas.
- Open and close the instrument several times to evenly distribute the oil and remove excess oil with a lint-free cloth. Subsequently, proceed to sterilize the instruments as the oil film is permeable to steam. It will act as a lubricant and anticorrosive without leaving stains on the instruments.
Sterilization:
- Sterilization of products taking into account the corresponding national requirements.
- Product sterilization must be carried out in a suitable sterilization container.