JAW WIDTH: Open width: 7.75 mm ± 0.5 mm | Closed width: 6 mm ± 0.5 mm
TYPE OF TIP: Flat cut
SPRING TYPE: Foldable single plate
STOCKAGE:
STORAGE:
Store at room temperature in a dry place.
Protect from heat, intense light, and dust.
WARNINGS:
Professional use.
The instrument must be cleaned, disinfected, and sterilized by the clinician before first use and after each use.
Check for proper functioning and perfect condition before using the product.
CLEANING AND CARE:
Initial Recommendations:
Perform a visual and mechanical check of the new surgical instruments.
Visible dirt should be removed as soon as possible to prevent residues from drying.
Avoid long waiting times for cleaning and disinfecting the instruments.
Preliminary manual cleaning:
Initially, it must be hand washed with mild soap.
In the operating room, the most apparent dirt must be removed as soon as possible to avoid encrustation that can lead to corrosion.
Long waiting times for reprocessing should be avoided (<1h).
Dry cleaning is preferable as medical devices can corrode if immersed for a long time in solutions.
If the dry process is insufficient, it will be necessary to wash them with cold water (<40ºC), including the cavities, grooves, and difficult-to-access holes that must be washed with pressurized water. Avoid leaving unwashed areas. You can use a soft plastic brush.
Dry thoroughly with an absorbent cloth that leaves no residue or with compressed air.
Cleaning and disinfection:
Immerse the products in a solution of distilled water with an appropriate disinfectant in an ultrasonic bath or tank.
Follow the instructions provided by the manufacturer of the disinfectant product to select the washing program, temperature, and time.
Clean instruments with movable joints in the open position or move the joints to avoid "shadow areas". Follow the manufacturer's instructions for disassembling removable instruments.
The instruments must be placed with minimal separation in the cleaning container and avoid overlapping them to prevent damage from collisions.
At the end of the disinfection program, wash the products thoroughly with plenty of cold distilled water, insisting thoroughly on the cavities, grooves, and difficult-to-access holes of the instrument, if possible with pressurized water.
Dry thoroughly with an absorbent cloth that leaves no residue or with compressed air.
Lubrication:
Use Sterilit Instrumental Protector (ref. 13.859.1 and 13.859.2) to protect the instruments.
Attach the white plastic tube provided with the spray and apply the aerosol oil directly to the joint area or hard-to-reach areas.
Open and close the instrument several times to evenly distribute the oil and remove excess oil with a lint-free cloth. Subsequently, proceed to sterilize the instruments as the oil film is permeable to steam. It will act as a lubricant and anticorrosive without leaving stains on the instruments.
Sterilization:
Sterilization of products taking into account the corresponding national requirements.
Product sterilization must be carried out in a suitable sterilization container.
Special Price€39.16Regular Price€48.95Taxes not included
https://herbitas.com/en/nipper-h476.html4932Nipper H476<p><strong>The Herbitas H476 nail clippers, 11.5cm with flat cut </strong>are made of stainless steel.</p>
<p>The flat cutting jaw features a straight cutting edge perpendicular to the nail surface and is used for cutting nails straight.</p>
<p> </p>
<p> </p>
<h3><strong>ALICATES USAGE INDICATIONS:</strong></h3>
<ul>
<li>Cutting nails and cuticles.</li>
<li>Manicure and pedicure product.</li>
<li>Reusable. Allows sterilization.</li>
</ul>
<p> </p>
<p> </p>
<h3><strong>TECHNICAL FEATURES:</strong></h3>
<p><strong>BRAND:</strong> Herbitas</p>
<p><strong>MATERIAL:</strong> Stainless steel</p>
<p><strong>STERILIZABLE:</strong> Sterilizable product. Reuse allowed.</p>
<p><strong>WEIGHT:</strong> 20g</p>
<p><strong>MEASURES:</strong> Total length of 11.5 cm ± 0.5 cm</p>
<p><strong>JAW LENGTH:</strong> Total length of 15 mm</p>
<p><strong>JAW WIDTH:</strong> Open width: 7.75 mm ± 0.5 mm | Closed width: 6 mm ± 0.5 mm</p>
<p><strong>TYPE OF TIP:</strong> Flat cut </p>
<p><strong>SPRING TYPE:</strong> Foldable single plate </p>
<p> </p>
<p><img src="{{media url="wysiwyg/fichas-producto/instrumental/AlicateHerbitasH476_medidas.JPG"}}" alt="" /></p><h3><strong>STOCKAGE:</strong></h3>
<p> </p>
<h3><strong>STORAGE:</strong></h3>
<ul>
<li>Store at room temperature in a dry place.</li>
<li>Protect from heat, intense light, and dust.</li>
</ul>
<p> </p>
<p> </p>
<h3><strong>WARNINGS:</strong></h3>
<ul>
<li>Professional use.</li>
<li>The instrument must be cleaned, disinfected, and sterilized by the clinician before first use and after each use.</li>
<li>Check for proper functioning and perfect condition before using the product.</li>
</ul>
<p> </p>
<p> </p>
<h3><strong>CLEANING AND CARE:</strong></h3>
<p>Initial Recommendations:</p>
<ul>
<li>Perform a visual and mechanical check of the new surgical instruments.</li>
<li>Visible dirt should be removed as soon as possible to prevent residues from drying.</li>
<li>Avoid long waiting times for cleaning and disinfecting the instruments.</li>
</ul>
<p>Preliminary manual cleaning:</p>
<ul>
<li>Initially, it must be hand washed with mild soap.</li>
<li>In the operating room, the most apparent dirt must be removed as soon as possible to avoid encrustation that can lead to corrosion.</li>
<li>Long waiting times for reprocessing should be avoided (<1h).</li>
<li>Dry cleaning is preferable as medical devices can corrode if immersed for a long time in solutions.</li>
<li>If the dry process is insufficient, it will be necessary to wash them with cold water (<40ºC), including the cavities, grooves, and difficult-to-access holes that must be washed with pressurized water. Avoid leaving unwashed areas. You can use a soft plastic brush.</li>
<li>Dry thoroughly with an absorbent cloth that leaves no residue or with compressed air.</li>
</ul>
<p>Cleaning and disinfection:</p>
<ul>
<li>Immerse the products in a solution of distilled water with an appropriate disinfectant in an ultrasonic bath or tank.</li>
<li>Follow the instructions provided by the manufacturer of the disinfectant product to select the washing program, temperature, and time.</li>
<li>Clean instruments with movable joints in the open position or move the joints to avoid "shadow areas". Follow the manufacturer's instructions for disassembling removable instruments.</li>
<li>The instruments must be placed with minimal separation in the cleaning container and avoid overlapping them to prevent damage from collisions.</li>
<li>At the end of the disinfection program, wash the products thoroughly with plenty of cold distilled water, insisting thoroughly on the cavities, grooves, and difficult-to-access holes of the instrument, if possible with pressurized water.</li>
<li>Dry thoroughly with an absorbent cloth that leaves no residue or with compressed air.</li>
</ul>
<p>Lubrication:</p>
<ul>
<li>Use Sterilit Instrumental Protector (ref. 13.859.1 and 13.859.2) to protect the instruments.</li>
<li>Attach the white plastic tube provided with the spray and apply the aerosol oil directly to the joint area or hard-to-reach areas.</li>
<li>Open and close the instrument several times to evenly distribute the oil and remove excess oil with a lint-free cloth. Subsequently, proceed to sterilize the instruments as the oil film is permeable to steam. It will act as a lubricant and anticorrosive without leaving stains on the instruments.</li>
</ul>
<p>Sterilization:</p>
<ul>
<li>Sterilization of products taking into account the corresponding national requirements.</li>
<li>Product sterilization must be carried out in a suitable sterilization container.</li>
</ul>https://herbitas.com/media/catalog/product/1/3/13.427.1_2.jpg15.6instock19.515.6203.9Herbitas000https://herbitas.com/media/catalog/product/1/3/13.427.1_2.jpg1117183118324489/Nippers2018-02-26T08:21:39+0000shop1