L-type Left-Handed Burr 429X (045) - Busch

SKU
14.031.1

Left-handed Tungsten Carbide Burr 429X (045) by Busch, with a rounded conical design for precision and durability.

Medium abrasion. Special for nail filing.

MAXIMUM SPEED: 65,000 rpm.

NOMINAL DIAMETER (045): 4.5 mm.

CUT: Crosscut.

TOOTHING: Medium cross.

 

 

€23.71 Taxes not included


Tungsten Carbide Bur 429X (045) BY BUSCH

The Tungsten Carbide Bur 429X (045) offers exceptional cutting performance thanks to its extremely hard material and specialized technical design. Ideal for specific podiatry applications such as treating nails affected by conditions like onychomycosis, artificial nails, and deformed nails. Its rounded conical design and medium crosscut teeth ensure precision, surface quality, and great durability.

INDICATIONS FOR USE OF THE PODIATRIC BUR:

  • Shaping the contour of nails with conditions like onychomycosis.
  • Shaping and treating artificial nails.
  • Controlled contouring of deformed nails.

TECHNICAL CHARACTERISTICS:

  • MATERIAL: Tungsten carbide.
  • MAXIMUM SPEED: 65,000 rpm.
  • NOMINAL DIAMETER (045): 4.5 mm.
  • SHAPE: Rounded conical.
  • CUT: Crosscut.
  • TOOTHING: Medium crosscut.

STORAGE:

  • Protect from direct sunlight.
  • Store in a clean, dry environment.

CLEANING AND CARE:

Initial preparation:
- Perform a visual and mechanical inspection of the bur's condition.
- Wash manually with water and neutral soap to remove visible dirt before disinfection.
Manual cleaning:
- Whenever possible, start with dry cleaning.
- If dry cleaning is insufficient, wash with cold water under pressure, ensuring to clean cavities, grooves, and hard-to-reach areas.
- Use brushes with plastic and soft bristles if necessary.
Disinfection:
- Immerse the burs in a suitable solution with distilled water and use an ultrasonic bath or tank.
- Select temperature, time, and program according to the disinfectant manufacturer's instructions.
Drying:
- Completely dry with an absorbent cloth that leaves no residue or with compressed air, especially in cavities and hard-to-reach areas.
Sterilization:
- Depending on the intended use, perform sterilization in an autoclave, considering recommended cycles (minimum 15 minutes at 121 °C or 3 minutes at 134 °C).
- Post-storage:
- Store the burs in a clean, dry place protected from direct sunlight to maintain their integrity and functionality.
- This procedure ensures the longevity of the burs and their safe use in healthcare environments.