Adson Brown Tweezers Dimeda

SKU
13.306.2

DIMEDA straight Adson Brown forceps, 12cm long with serrated jaws.

Your crocodile forceps at the best price!.

€11.45 Taxes not included

The DIMEDA Adson Brown forceps are straight serrated forceps, 12cm long with striated jaws and are made of stainless steel.

With striated handle for better grip!.

USAGE INDICATIONS OF THE FORCEPS:

  • Dissection forceps for use in implantology and surgery.
  • Used to grasp and separate superficial and delicate tissue in surgical procedures.
  • Class I medical device.
  • Reusable. Allows sterilization.

TECHNICAL CHARACTERISTICS:

BRAND: Dimeda

MATERIAL: Stainless steel

STERILIZABLE: Sterilizable product. Reusable

WEIGHT: 20g

MEASUREMENTS: 12cm x 1.4cm

JAW TYPE: Crocodile or serrated jaws with 7 x 7 teeth

STORAGE:

  • Store at room temperature in a dry place.
  • Protect from heat, intense light, and dust.

 

 

WARNINGS:

  • For professional use.
  • The instrument must be cleaned, disinfected, and sterilized by the clinician before first use and after each use.

 

 

CLEANING AND CARE:

Preliminary manual cleaning:

  • Initially, it must be hand washed with mild soap.
  • In the operating room, the most apparent dirt must be removed as soon as possible to avoid encrustation that can lead to corrosion.
  • Long waiting times for reprocessing should be avoided (<1h).
  • Dry cleaning is preferable as medical devices can corrode if immersed for a long time in solutions.
  • If the dry process is insufficient, it will be necessary to wash them with cold water (<40ºC), including the cavities, grooves, and difficult-to-access holes that must be washed with pressurized water. Avoid leaving unwashed areas. You can use a soft plastic brush.
  • Dry thoroughly with an absorbent cloth that leaves no residue or with compressed air.

Cleaning and disinfection:

  • Immerse the products in a solution of distilled water with an appropriate disinfectant in an ultrasonic bath or tank.
  • Follow the instructions provided by the manufacturer of the disinfectant product to select the washing program, temperature, and time.
  • Clean instruments with movable joints in the open position or move the joints to avoid "shadow areas". Follow the manufacturer's instructions for disassembling removable instruments.
  • The instruments must be placed with minimal separation in the cleaning container and avoid overlapping them to prevent damage from collisions.
  • At the end of the disinfection program, wash the products thoroughly with plenty of cold distilled water, insisting thoroughly on the cavities, grooves, and difficult-to-access holes of the instrument, if possible with pressurized water.
  • Dry thoroughly with an absorbent cloth that leaves no residue or with compressed air.

Sterilization:

  • Sterilization of products considering the corresponding national requirements. Product sterilization must be carried out in a suitable sterilization container according to DIN EN ISO 11607-1 and EN 868 standards.
  • Sterilization must be carried out by a fractional pre-vacuum process with the following parameters: 134°C, 5 min waiting time, 3 pre-vacuum cycles. Vacuum drying for at least 20 min.